What are the air inlet & outlet fittings on the KMACS-5?
What are the air inlet & outlet fittings on the KMACS-5?
The LP inlet: #8 male JIC
The primary air outlets: #6 male JIC
The pneumo outlets#4 male JIC
Can I get the KMACS-5 without its case?
Can I get the KMACS-5 without its case?
The case (p/n 420-101) is an integral part of the design, building & shipping of the precision made interior workings of the KMACS-5. We therefore do not offer the KMACS-5 without the case. All KMACS-5s leave our factory installed into their cases.
I need an inspection on my Kirby Morgan product. Do I send it to Kirby Morgan?
I need an inspection on my Kirby Morgan product. Do I send it to Kirby Morgan?
We ask that you send it to one of our authorized dealers for inspections.
Does Kirby Morgan offer quick disconnects?
Does Kirby Morgan offer quick disconnects?
We do not make or handle Quick Disconnects (quick disconnect whip assembly - for between the sideblock emergency valve and the divers bailout bottle first stage regulator) but you would be able to source quick disconnects through many of our dealers. Please see our authorized dealers.
The most often asked for thread sizes?
The most often asked for thread sizes?
Brass Adapter (on One Way Valve): 1/4 inch NPT-O2
Emergency Valve Outlet: 9/16 -18 inch UNF 2A (USA “standard scuba”)
Small LP Ports 3/8 inch-24 UNF 2B
Large LP Ports 1/2 inch -20 UNF 2A
KM Diamond Water Shroud Kit
| Part # | Description | Qty. |
|---|---|---|
| 510-731 | Shroud, Diamond Valve | 1 |
| 510-732 | Shroud, Inhale Regulator | 1 |
| 510-733 | Access Cover | 1 |
| 510-734 | Shroud, Side Block | 1 |